Part names and
Functions
Setting defaultsConnections Playback
Selecting
Files and
Folders
Getting Started
Information
72
Selecting
Media
Recording Edit Function
Control
Function
Serial remote control function
D&M RC communication format
n Configuration of control commands
The packets of control commands start with the Start Character
“@”,andendwiththeEndCharacter“0x0D”asshownbelow.
COMMAND
ID
0
Start
Character
End
Character
\r (0x0D)
@
n Configuration of command codes
Item Value (Hex value within parentheses)
Start Character ‘@’(0x40)
ID ‘0’ (0x30)
Command Indicates the command details.
End Character ‘\r’ (0x0D)
Response timeout is 100msec.
n ACK (received successfully) and NACK (receive
failed) command codes
Content
Hex
value
Transmission conditions
ACK 0x06 –
NACK 0x15 •When an End Character (0x0D) is received
withnoStartCharacter“@”
•When a command that does not exist is
received
•When there is a space more than 5msec
between command characters
•When a command is received, ACK or NACK is returned within 100
msec.
•If there is no response after 100 msec, the next command is
permitted.
q External control and operation of the DN-700R
When the DN-700R receives a control command from the host, the
DN-700R sends ACK (received successfully) to the host and executes
the command.
ACK
DN-700R
Host device
However, if data other than a specified command or an End Character
(0x0D)withnoStartCharacter‘@’isreceived,receivefailsandNACK
is returned.
w Status information output for external status
request commands
When a status request is received from the host, the DN-700R returns
ACK and a response to the request details.
ACK
DN-700R
Host device
Status request
command
Status information
command
Sequence diagram of status request command
However, if data other than a specified command or an End Character
(0x0D)withnoStartCharacter(‘@’)isreceived,receivefailsandNACK
is returned.
Control command